Dwelling requirements and bathrooms (ITC-BT-26 and 27)

视频即将上线

ITC-BT-26 gathers the practical installation requirements in dwellings, and ITC-BT-27 those for bathrooms and showers, which is the most dangerous place in the house because of the combination of water, a wet body and electricity. Understanding both documents avoids the most serious mistakes in renovations.

General dwelling requirements (ITC-BT-26)

  • Each circuit runs in its own conduit or is grouped in a controlled way.
  • All socket outlets have an earth contact.
  • Conductors of different circuits are not mixed in one box without separation.
  • There is a minimum separation from water, gas and heating pipes.
  • Junction boxes and accessories have the protection suitable for their location.

ITC-BT-26 also regulates the minimum and maximum distances of accessories from the floor and from other installations, and the panel location. The exact heights and distances are in the current ITC, and it is advisable to apply them with a template or sketch before chasing the walls.

The bathroom (ITC-BT-27)

ITC-BT-27 divides the space around the bath or shower into volumes numbered 0 to 3, from most to least exposure to water. In volume 0 (inside the bath) only very specific safety extra-low-voltage equipment is allowed; in volumes 1 and 2 the type of appliances is limited and high IP protection degrees are required; in volume 3 the requirements are relaxed. The dimensions of each volume and the exact IP degrees are in the current ITC.

text
Volumen 0: interior de la bañera/ducha     (más riesgo)
Volumen 1: sobre la bañera, hasta una altura
Volumen 2: franja alrededor del volumen 1
Volumen 3: zona exterior con menos exigencias
(medidas y grados IP: consultar la ITC-BT-27 vigente)

What always applies in the bathroom

  • 30 mA RCD on the bathroom circuits.
  • Local equipotential bonding of metal parts.
  • Do not install switches or sockets in the most exposed volumes.
  • Use accessories with the right IP degree in each volume.

Practical case: in a renovation, the client asks for a socket by the washbasin for the hair dryer. The washbasin is usually outside the most exposed volumes, but you must measure from the edge of the bath or shower to check which volume it falls in, use a socket with adequate protection degree and confirm the circuit is protected by a 30 mA RCD. A two-minute measurement avoids a significant risk.

text
Lista de comprobación del baño / Bathroom checklist:
  [ ] volúmenes medidos desde el borde de la bañera/ducha
  [ ] grado IP de cada mecanismo según su volumen
  [ ] diferencial 30 mA en el circuito
  [ ] conexión equipotencial local realizada

Before handing over a bathroom renovation, go through that list with the client. It is a brief check that can be shown in the certificate and that makes safety visible: the user sees what was done and why, and the next electrician to open the bathroom understands how it was built.